Bard W17L1 Dokumentacja

Przeglądaj online lub pobierz Dokumentacja dla Klimatyzatory typu split Bard W17L1. Bard W17L1 Specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
Manual 2100-508D
Page 1 of 25
INSTALLATION INSTRUCTIONS
WALL MOUNTED
PACKAGE AIR CONDITIONERS
MODELS
W17A1 W17L1
W18A1 W18L1
W24A1 W24L1
W30A1 W30L1
W36A1 W36L1
W42A1 W42L1
W48A1 W48L1
W60A1 W60L1
W70A1 W70L1
Manual : 2100-508D
Supersedes: 2100-508C
File: Volume III Tab 16
Date: 09-21-10
Bard Manufacturing Company, Inc.
Bryan, Ohio 43506
Since 1914...Moving ahead just as planned.
Przeglądanie stron 0
1 2 3 4 5 6 ... 24 25

Podsumowanie treści

Strona 1 - Bryan, Ohio 43506

Manual 2100-508DPage 1 of 25INSTALLATION INSTRUCTIONSWALL MOUNTEDPACKAGE AIR CONDITIONERSMODELSW17A1 W17L1W18A1 W18L1W24A1 W24L1W30A1 W30L1W36A1 W36

Strona 2 - Contents

Manual 2100-508DPage 10 of 25FIGURE 3CW42A1, W42L1, W48A1, W48L1, W60A1, W60L1, W70A1, W70L1MOUNTING INSTRUCTIONSD16"16"16"16"16&

Strona 3 - THESE PUBLISHERS:

Manual 2100-508DPage 11 of 25FIGURE 4ELECTRIC HEAT CLEARANCEW30A1, W30L1, W36A1, W36L1, W42A1, W42L1, W48A1, W48L1, W60A1, W60L1, W70A1, W70L1

Strona 4 - SHIPPING DAMAGE

Manual 2100-508DPage 12 of 25FIGURE 5WALL MOUNTING INSTRUCTIONSFIGURE 6WALL MOUNTING INSTRUCTIONSDUCTOPENINGRETURN AIRSUPPLY AIRWOOD FRAME WALL INST

Strona 5 - CONDENSATE DRAIN

Manual 2100-508DPage 13 of 25FIGURE 7COMMON WALL MOUNTING INSTALLATIONSLOWEREDRAISED FLOORRAFTERSSUPPLY AIRCEILING SURFACEWALL SLEEVERETURN AIRCLOSET

Strona 6

Manual 2100-508DPage 14 of 25WIRING – MAIN POWERRefer to the unit rating plate for wire sizing informationand maximum fuse or “HACR” type circuit br

Strona 7 - Page 7 of 25

Manual 2100-508DPage 15 of 25START UPTHESE UNITS REQUIRE R-410AREFRIGERANT AND POLYOLESTER OIL.GENERAL:1. Use separate service equipment to avoid cros

Strona 8 - FIGURE 3A

Manual 2100-508DPage 16 of 25START UP (Continued)IMPORTANT INSTALLER NOTEFor improved start up performance wash the indoor coilwith a dish washing det

Strona 9 - W30A1, W30L1, W36A1, W36L1

Manual 2100-508DPage 17 of 25SEQUENCE OF OPERATIONCOOLING – Circuit R-Y makes at thermostat pullingin compressor contactor, starting the compressor

Strona 10 - MOUNTING INSTRUCTIONS

Manual 2100-508DPage 18 of 25TROUBLESHOOTINGFIGURE 8FAN BLADE SETTINGMIS-1724TABLE 1FAN BLADE DIMENSIONREMOVAL OF FAN SHROUD1. Disconnect all power

Strona 11 - WARNING

Manual 2100-508DPage 19 of 25TABLE 3COOLING PRESSURE TABLEAir Temperature Entering Outdoor Coil °FLow side pressure ± 2 PSIGHigh side pressure ± 5 P

Strona 12 - FIGURE 6

Manual 2100-508DPage 2 of 25ContentsFiguresFigure 1 Fresh Air Damper Assembly ... 5Figure 2 Unit Dimensions ...

Strona 13 - DUCTED SUPPLY

Manual 2100-508DPage 20 of 25TABLE 41 Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors.2

Strona 14 - WIRING – LOW VOLTAGE WIRING

Manual 2100-508DPage 21 of 25TABLE 51 Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors.2

Strona 15 - WARNING

Manual 2100-508DPage 22 of 25TABLE 6RECOMMENDED AIRFLOWTABLE 7INDOOR BLOWER PERFORMANCETABLE 8MAXIMUM ESP OF OPERATIONELECTRIC HEAT ONLYValues show

Strona 16 - START UP (Continued)

Manual 2100-508DPage 23 of 25TABLE 9ELECTRIC HEATsledoM1-V0421-V8023-V0423-V8023-V064WKspmAHUTBspmAHUTBspmAHUTBspmAHUTBspmAHUTB47.61056314.410420158.

Strona 17 - PRESSURE SERVICE PORTS

Manual 2100-508DPage 24 of 25W17/18A1-AW24A1-AW24A1-BW24A1-CW30A1-AW30A1-BW30A1-CW36A1-AW36A1-BW36A1-CW42A1-AW42A1-BW42A1-CW48A1-AW48A1-BW48A1-CW60A1-

Strona 18 - TROUBLESHOOTING

Manual 2100-508DPage 25 of 25TABLE 11VENT & CONTROL OPTIONSW17, W18, W24W30, W36W42, W48, W60, W70rebmuNtraPnoitpircseD41-CMCTDO XXX51-CMC)esahP-

Strona 19 - COOLING PRESSURE TABLE

Manual 2100-508DPage 3 of 25GETTING OTHER INFORMATION AND PUBLICATIONSThese publications can help you install the airconditioner or heat pump. You ca

Strona 20 - TABLE 4

Manual 2100-508DPage 4 of 25WALL MOUNT GENERAL INFORMATIONAIR CONDITIONER WALL MOUNT MODEL NOMENCLATUREW 42 A 1– A 10 X X X X X ANOTE: Vent options X

Strona 21 - TABLE 5

Manual 2100-508DPage 5 of 25DUCT WORKAll duct work, supply and return, must be properly sizedfor the design airflow requirement of the equipment. Air

Strona 22 - Page 22 of 25

Manual 2100-508DPage 6 of 25sseccAecivreSrofderiuqeRsecnaraelCwolfriAresnednoCetauqedAdnaSLEDOM EDISTFEL EDISTHGIRA63W,A03W,A42W,A81W,A71W "51 &q

Strona 23 - ELECTRIC HEAT

Manual 2100-508DPage 7 of 25IACK2.13HJ2.639.06PMLOE.44W5.75FGRSSSSSTDReturn Air OpeningMIS-2488 BDrainInletAirAir OutletFront ViewSide ViewCond.1Back

Strona 24 - PULL DISCONNECT (WMPD)

Manual 2100-508DPage 8 of 25FIGURE 3AW17A1, W17L1, W18A1, W18L1, W24A1, W24L1MOUNTING INSTRUCTIONS12"12"12"12"12"20"20&

Strona 25 - VENT & CONTROL OPTIONS

Manual 2100-508DPage 9 of 25FIGURE 3BW30A1, W30L1, W36A1, W36L1MOUNTING INSTRUCTIONSD12"12"12"12"12"C CA28"1"3&quo

Komentarze do niniejszej Instrukcji

Brak uwag